-40%

Solaredge SE3800H-USS3BBC14 Energy Hub Inverter with Prism Technology

$ 739.2

Availability: 51 in stock
  • Condition: New
  • Brand: Solaredge
  • All returns accepted: ReturnsNotAccepted
  • Model: Solaredge SE3800H-USS3BBC14

    Description

    Single Phase Energy Hub
    Inverter with Prism Technology for North America
    SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
    Optimized battery storage with HD-Wave technology
    Record-breaking 99% weighted efficiency with 200% DC oversizing
    Small, lightweight, and easy to install
    Modular design, future ready with optional upgrades to:
    DC-coupled storage for full or partial home backup Built-in consumption monitoring
    Direct connection to the SolarEdge smart EV charger
    Multi-inverter, scalable storage solution
    Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12
    Embedded revenue grade production data, ANSI C12.20 Class 0.5
    solaredge.com
    12-25
    YEAR WARRANTY
    HOME BACKUP
    Single Phase Energy Hub Inverter
    with Prism Technology for North America
    SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
    SE3000H-US
    SE3800H-US
    SE6000H-US
    SE7600H-US
    UNITS
    OUTPUT - AC ON GRID
    Rated AC Power
    3000
    3800
    6000
    7600
    W
    Maximum AC Power Output
    3000
    3800
    6000
    7600
    W
    AC Output Voltage Range
    211-264
    Vac
    AC Frequency Range (min - nom - max)
    59.3 - 60 - 60.5(2)
    Hz
    Maximum Continuous Output Current
    12.5
    16
    25
    32
    A
    GFDI Threshold
    1
    A
    Total Harmonic Distortion (THD)
    <3
    %
    Power Factor
    1, adjustable -0.85 to 0.85
    Utility Monitoring, Islanding Protection, Country Configurable Thresholds
    Yes
    Charge Battery from AC (if allowed)
    Yes
    Typical Nighttime Power Consumption
    <2.5
    W
    OUTPUT - AC BACKUP(3)
    Rated AC Power in Backup Operation(4)
    AC L-L Output Voltage Range in Backup
    AC L-N Output Voltage Range in Backup
    AC Frequency Range in Backup (min - nom - max)
    Maximum Continuous Output Current in Backup Operation
    3000 3800 7600*
    12.5 16 32*
    211 - 264
    105 - 132 55 - 60 - 65
    6000
    25
    7600 W
    Vac Vac Hz
    32 A
    GFDI 1A THD <5%
    OUTPUT - SMART EV CHARGER AC
    Rated AC Power
    AC Output Voltage Range
    AC Frequency Range (min - nom - max)
    Maximum Continuous Output Current @240V (grid, PV and battery)
    9600 W 211 - 264 Vac 59.3 - 60 - 60.5 Hz 40 Aac
    INPUT - DC (PV AND BATTERY)
    Transformer-less, Ungrounded
    Yes
    Max Input Voltage
    480
    Vdc
    Nom DC Input Voltage
    380
    Vdc
    Reverse-Polarity Protection
    Yes
    Ground-Fault Isolation Detection
    600k? Sensitivity
    INPUT - DC (PV)
    Maximum DC Power
    6000
    7600
    12000
    15200
    W
    15200*
    Maximum Input Current(5)
    8.5
    10.5
    16.5
    20
    Adc
    20*
    Max. Input Short Circuit Current
    45
    Adc
    Maximum Inverter Efficiency
    99.2
    %
    CEC Weighted Efficiency
    99
    %
    2-pole Disconnection
    Yes
    INPUT - DC (BATTERY)
    Supported Battery Types
    Number of Batteries per Inverter Maximum Battery Capacity per Inverter Continuous Power Per Inverter(8)
    Peak Power(8)
    Max Input Current @240V
    2-pole Disconnection
    LG Chem RESU 10H & RESU16H Prime(6) 1 or 2(7)
    19.6 kWh 5000 W 7000 W
    18 Adc Yes
    Single Phase Energy Hub Inverter
    with Prism Technology for North America
    SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
    Built - in(9)
    With Backup Interface (purchased separately) for service up to 200A; Up to 3 inverters, 15kW backup power, and 60kWh backup capacity
    Direct connection to Smart EV charger
    RS485, Ethernet, Wi-Fi (optional), Cellular(10)
    Built - in(9)
    Yes
    With the SetApp mobile application using built-in Wi-Fi Access Point for local connection Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12
    UL1741, UL1741 SA, UL1741 PCS, UL1699B, UL1998, UL9540, CSA 22.2 IEEE1547, Rule 21, Rule 14H
    FCC part 15 class B
    SMART ENERGY CAPABILITIES
    Consumption Metering
    SE3000H-US
    SE3800H-US
    SE6000H-US
    SE7600H-US
    UNITS
    Backup & Battery Storage
    EV Charging
    ADDITIONAL FEATURES
    Supported Communication Interfaces
    Revenue Grade Metering, ANSI C12.20
    Integrated AC, DC and Communication Connection Unit
    Inverter Commissioning
    DC Voltage Rapid Shutdown (PV and Battery)
    STANDARD COMPLIANCE
    Safety
    Grid Connection Standards
    Emissions
    INSTALLATION SPECIFICATIONS
    AC Output Conduit Size / AWG Range
    EV AC Output Conduit Size / AWG Range
    DC Input (PV) Conduit Size / AWG Range
    DC Input (Battery) Conduit Size / AWG Range
    Dimensions with Connection Unit (H x W x D)
    Weight with Connection Unit
    Noise
    Cooling
    Operating Temperature Range
    Protection Rating
    3/4'' maximum / 14-8 AWG
    3/4'' maximum / 14-8 AWG
    3/4'' maximum / 14-8 AWG
    3/4'' maximum / 14-8 AWG
    26 / 11.8 < 25
    3/4'' maximum / 14-8 AWG 1'' maximum / 14-4 AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-64AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG* 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG*
    1'' maximum / 14-4 AWG
    1'' maximum / 14-4 AWG
    1'' maximum / 14-6 AWG
    1'' maximum / 14-6 AWG
    17.7 x 14.6 x 6.8 / 450 x 370 x 174
    26 / 11.8 30.2 / 13.7* < 25
    < 50*
    Natural Convection -40 to +140 / -40 to +60(11) NEMA 4
    30.2 / 13.7
    < 50
    in / mm lb / kg
    dBA  ?F /  ?C
    * Supported with PN SE3800H-USMxxxxxx
    (1) These specifications apply to inverters with part numbers SExxxxH-USS3Bxxxx, SE3800H-USMxxBCxx or SE7600H-USSSHxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support
    (3) Not designed for standalone applications and requires AC for commissioning
    (4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated
    (5) A higher current source may be used; the inverter will limit its input current to the values stated
    (6) Requires supporting inverter FW for RESU16H Prime battery
    (7) When connecting two LG Chem RESU10H batteries, each battery must have a different part number. LG Chem RESU16H Prime is supported with a single battery only
    (8) Discharge power is limited up to inverter rated AC power
    (9) For consumption metering current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box.
    Revenue grade metering is only for production metering (10) For all cellular plans customer must verify that:
    · Customer is responsible for verifying that the site location has adequate mobile coverage by the third party service provider prior to any installation by accessing https://www.solaredge.com/products/ communication/cellular-communication-options#/
    · SolarEdge shall not be responsible or liable for unavailability or discontinuance of network coverage in a specific area or region, any network downtime, or permanent service shutdown (11) Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
    Single Phase Energy Hub Inverter
    with Prism Technology
    for North America
    SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1)
    Connecting CTs to the Revenue Grade and Consumption Meter
    Single Phase Energy Hub Inverter with Prism Technology
    Grid
    © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2021/V02/ENG NAM. Subject to change without notice.